Recent Installations
Simple Cycle Catalyst Systems for Pratt & Whitney FT8 TwinPacs
KLAMATH FALLS, OREGON
- (4) Units - (56 MW per TwinPac)
- Catalyst Systems: NOx (SCR) Retrofit (CO pre-existing)
Simple Cycle Catalyst System for ABB GT10B2
CLATSKANIE, OREGON
- (1) Unit - (25 MW) Gas Turbine
- Catalyst Systems: CO Only
Simple Cycle Catalyst Systems for GE LM6000
WEST VALLEY, UTAH
- (4) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
SALT LAKE CITY, UTAH
- (3) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
PASADENA, CALIFORNIA
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
RIPON, CALIFORNIA
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
RIVERSIDE, CALIFORNIA
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst System for GE LM6000
SAN DIEGO, CALIFORNIA
- (1) Unit - (45 MW) Gas Turbine
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
LOS ANGELES, CALIFORNIA
- (5) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
NILAND, CALIFORNIA
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst System for GE LM6000
YUMA, ARIZONA
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst System for GE LM6000
MIRAMAR, CALIFORNIA
- (1) Unit - (45 MW) Gas Turbine
- Catalyst System: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
WINCHESTER, TEXAS
- (4) Units (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
AUSTIN, TEXAS
- (2) Units - (45 MW) Gas Turbines
- Catalyst Systems: NOx Only
Simple Cycle Catalyst Systems for GE LMS100
LAREDO, TEXAS
- (2) Units - (100 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Heat Recovery Steam Generators for GE Frame 6B
ANACORTES, WASHINGTON
- (2) Units - (40 MW) Gas Turbines
- HP Steam: 300,000 lb/hr - 650 psig @ 720ºF
Heat Recovery Steam Generators for GE Frame 6B
ANACORTES, WASHINGTON
- (3) Units - (40 MW) Gas Turbines
- HP Steam: 300,000 lb/hr - 650 psig @ 720ºF
Heat Recovery Steam Generator for GE Frame 6B
NORTH TONAWANDA, NEW YORK
- (1) Unit - (40 MW) Gas Turbine
- HP Steam: 135,000 lb/hr - 1265 psig @ 950ºF
- LP Steam: 27,000 lb/hr - 305 psig @ 487ºF
Heat Recovery Steam Generators for GE Frame 6B
MONTEGO BAY, JAMAICA
- (2) Units - (40 MW) Gas Turbines
- HP Steam: 148,000 lb/hr - 986 psig @ 977ºF
- LP Steam: 10,7000 lb/hr - 98 psig @ 483ºF
Heat Recovery Steam Generator for GE Frame 6FA
PINION PINES, NEVADA
- (1) Unit (70 MW) Gas Turbine
- HP Steam: 175,000 lb/hr - 943 psig @ 950ºF
- LP Steam: 45,000 lb/hr - 48 psig @ 350ºF
- Superheat Steam: 155,000 lb/hr - 943 psig @ 950ºF
Heat Recovery Steam Generators for GE Frame 7EA
POINT COMFORT, TEXAS
- (5) Units - (85 MW) Gas Turbines
- HP Steam: 364,000 lb/hr - 1350 psig @ 905ºF
- LP Steam: 60,000 lb/hr - 300 psig @ 500ºF
Heat Recovery Steam Generator for GE Frame 7EA
GAINESVILLE, FLORIDA
- (1) Unit (85 MW) - Gas Turbine
- HP Steam: 284,000 lb/hr - 925 psig @ 955ºF
- LP Steam: 52,000 lb/hr - 36 psig @ 304ºF
Heat Recovery Steam Generators for GE Frame 7EA
SASKATOON, SASKATCHEWAN, CANADA
- (2) Units - (85 MW) Gas Turbines
- HP Steam: 582,000 lb/hr - 1381 psig @ 967ºF
- IP Steam: 10,000 lb/hr - 308 psig @ 452ºF
- LP Steam: Sufficient for Integral Deaeration
Heat Recovery Steam Generators for GE Frame 7FA
DENVER CITY, TEXAS
- (2) Units - (165 MW) Gas Turbines
- HP Steam: 556,380 lb/hr - 1538 psig @ 990ºF
- Reheat Steam: 474,598 lb/hr - 358 psig @ 1005ºF
- IP Steam: 42,691 lb/hr - 376 psig @ 621ºF
- LP Steam: 2,501 lb/hr - 65 psig @ 467ºF
Heat Recovery Steam Generators for Siemens V84.3A
GLENNONVILLE, MISSOURI
- (2) Units - (170 MW) Gas Turbines
- HP Steam: 373,000 lb/hr - 1645 psig @ 1003ºF
- Reheat Steam: 450,000 lb/hr - 396 psig @ 1003ºF
- IP Steam: 83,000 lb/hr - 405 psig @ 610ºF
- LP Steam: 51,4000 lb/hr - 51 psig @ 459ºF
Heat Recovery Steam Generators for EGT Typhoons
HANOVER PARK, ILLINOIS
- (3) Units - (4 MW) Gas Turbine
- HP Steam: 34,000 lb/hr - 615 psig @ 750ºF
- LP Steam: Sufficient for Integral Deaeration
Heat Recovery Steam Generator for ABB GT10
CAMBRIDGE, MASSACHUSETTS
- (1) Unit - (25 MW) Gas Turbine
- LP Steam: 166,000 lb/hr - 232 psig @ 450ºF
Heat Recovery Steam Generators for Rolls Royce RB211
VILLAHERMOSA, MEXICO
- (2) Units - (27.5 MW) Gas Turbines
- HP Steam: 94,900 lb/hr - 900 psig @ 950ºF
- LP Steam: Sufficient for Integral Deaeration
Heat Recovery Steam Generator for Siemens SGT800
REDDING, CALIFORNIA
- (1) Unit - (40 MW) Gas Turbine
- HP Steam: 140,000 lb/hr - 637 psig @ 755ºF
- LP Steam: Sufficient for Integral Deaeration
Heat Recovery Steam Generator for Siemens SGT700
CALLAO, PERU
- (1) Unit - (29 MW) Gas Turbine
- HP Steam: 127,900 lb/hr - 667 psig @ 806ºF
Heat Recovery Steam Generator for GE LM2500
LUBBOCK, TEXAS
- (1) Unit - (23 MW) Gas Turbine
- HP Steam: 65,000 lb/hr - 645 psig @ 750ºF
- LP Steam: Integral Deaerator
Heat Recovery Steam Generators for GE LM2500
TUPMAN, CALIFORNIA
- (2) Units - (23 MW) Gas Turbine
- HP Steam: 145,000 lb/hr - 515 psig @ 604ºF
Heat Recovery Steam Generator for GTX100
REDDING, CALIFORNIA
- (1) Unit - (42 MW) Gas Turbine
- HP Steam: 140,000 lb/hr - 637 psig @ 755ºF
- LP Steam: Sufficient for Integral Deaeration
Heat Recovery Steam Generators for GE LM6000
CARSELAND, ALBERTA, CANADA
- (2) Units - (43MW) Gas Turbines
- HP Steam: 249,000 lb/hr - 907 psig @ 797ºF
Heat Recovery Steam Generator for GE LM6000
MODESTO, CALIFORNIA
- (1) Unit (42 MW) Gas Turbine
- HP Steam: 273,500 lb/hr - 1,300 psig @ 955º
- LP Steam: 9,000 lb/hr - 102 psig @ 600ºF
Heat Recovery Steam Generators for GE LM6000
Santa Clara, California
- (2) Units - (45 MW) Gas Turbine
- HP Steam: 184,000 lb/hr - 1,275 psig @ 995ºF
- LP Steam: 33,000 lb/hr - 105 psig @ 581ºF
Simple Cycle Catalyst System for GE LMS100
MILLVILLE, NEW JERSEY
- (1) Unit (100 MW) Gas Turbine
- Catalyst Systems: CO and NOx
Simple Cycle Catalyst Systems for GE LMS100
EDMONTON, ALBERTA, CANADA
- (2) Units (100 MW) Gas Turbines
- Catalyst Systems: NOx only
Simple Cycle Catalyst Systems for GE LMS100
TRAPP, KENTUCKY
- (2) Units (100 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst System for GE LM6000
ST. GEORGE, UTAH
- (1) Unit - (45 MW) Gas Turbine
- Catalyst Systems: NOx and CO
Simple Cycle Catalyst Systems for GE LM6000
MILFORD, CONNECTICUT
- (4) Units (45 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Direct Fired Heaters
LAKE CHARLES, LOUISIANA
- (2) Units - 150.00 MM BTU/hr
- Glycol Heaters / Burner Management Skids
Simple Cycle Catalyst Systems for GE LM6000
Coolidge, Arizona
- (12) Units - (45 MW) Gas Turbines
- Catalyst Systems: CO and NOx
Simple Cycle Catalyst Systems for GE LMS100
LAREDO, TEXAS
- (2) Units (100 MW) Gas Turbines
- Catalyst Systems: NOx and CO
Heat Recovery Steam Generator for GE LM6000
Houston, Texas
- (1) Unit - (43 MW) Gas Turbine
- HP Steam: 237,000 lb/hr - 435 psig @ 600ºF
- LP Steam: 97,000 lb/hr - 170 psig Sat
- Supplement Firing - 220 mm BTU/hr
- Catalyst System: NOx
Heat Recovery Steam Generator for GE LM2500+G4
COLLEGE STATION, TEXAS
- (1) Unit - (33 MW) Gas Turbine
- HP Steam: 192,000 lb/hr - 450 psig @ 665ºF
- Supplemental Firing: 115 mm BTU/hr